Skip to main content
Siemens 3VA2010-6HN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2010-6HN32-0KL0 MCCB, 100 A, 3-Pole, 242

MPN3VA2010-6HN32-0KL0

Siemens SENTRON 3VA series molded case circuit breaker, 3VA2010-6HN32-0KL0, 100 A continuous, 3-pole, 242 kA breaking capacity at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-6HN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20106HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2010-6HN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-6HN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-6HN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-6HN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2010-6HN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-6HN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers for the panel

The Siemens SENTRON 3VA2010-6HN32-0KL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its breaking capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, and 121 kA at 500 V, dropping to 3 kA at 690 V. That means it handles high-fault utility feeds and transformer secondaries without cascading upstream, a key consideration for selectivity studies. Designed for line protection, this MCCB carries a shunt trip release (STL) and a complement of auxiliary switches: two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ designation). The trip indicator and voltage trigger are present; undervoltage release and ground-fault monitoring are not fitted on this variant. Panel integration is straightforward — the 105 mm width, 181 mm height, and 86 mm depth fit standard SENTRON 3VA mounting footprints. Maximum power loss is 13.5 W, so thermal budgeting inside the enclosure is manageable. Operating temperature range is -25 °C to 70 °C, with storage from -40 °C to 80 °C.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

187 kA at 415 V, which is the same rating as at 440 V. At 240 V it reaches 242 kA.

How do I get current pricing and availability for 3VA2010-6HN32-0KL0?

Submit an RFQ through this listing — availability and current pricing are confirmed at quote time through independent distribution channels.

Does this MCCB include a shunt trip release?

Yes, it is fitted with a shunt trip (STL) release, plus two auxiliary switches, one trip alarm switch, and one electrical alarm switch.

MPN
3VA2010-6HN32-0KL0