Skip to main content
Siemens 3VA2010-6HN36-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2010-6HN36-0DL0 MCCB, 100A, 3-Pole, 242kA

MPN3VA2010-6HN36-0DL0

Siemens SENTRON 3VA2010-6HN36-0DL0, molded case circuit breaker, 3-pole, 100 A continuous, 242 kA interrupting at 240 V, line protection design, undervoltage release, 86 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6HN36-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20106HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2010-6HN36-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.16 W
3VA2010-6HN36-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-6HN36-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6HN36-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2010-6HN36-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6HN36-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-6HN36-0DL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed within that span, per the datasheet. Interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The trip indicator is present, and there is no voltage-trigger function or communication module on this variant.

The width and height are standard for a 100 A 3-pole MCCB in the SENTRON 3VA platform; it mounts via the standard DIN-rail or screw-mount pattern typical of this frame size.

Electrical characteristics and thermal limits

Maximum power loss is 16 W.

As a Siemens SENTRON product, this MCCB carries the standard compliance documentation for industrial control gear: CE marking for the European market, and UL/CSA listing for North American installations. RoHS and REACH declarations are available from the manufacturer. No ground-fault monitoring version is included on this order code.

Frequently asked questions

Where can I buy 3VA2010-6HN36-0DL0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

When sourcing 3VA2010-6HN36-0DL0, what's the closest functional second-source — 3VA1110-5EF32-0AM0?

The 3VA1110-5EF32-0AM0 is a different frame size and rating within the same SENTRON 3VA family. It will not drop into the same panel cutout or bus connection without re-engineering the mounting and bus bars. The 3VA2010-6HN36-0DL0 is a 100 A, 3-pole line-protection breaker with UVR and a specific auxiliary switch complement; the 3VA1110 series is a smaller frame. Verify your panel's ampacity and physical footprint before substituting.

What is 3VA2010-6HN36-0DL0's listed depth (86 mm) on this component line?

The depth is 86 mm (3.39 in). This is the body depth; allow additional clearance for wiring and cable bending radius behind the breaker.

What is 3VA2010-6HN36-0DL0's listed width (105 mm) on this component line?

The width is 105 mm (4.13 in). This is the standard width for a 3-pole 100 A MCCB in the SENTRON 3VA platform.

Will 3VA2010-6HN36-0DL0 drop into a panel that was specified around 3VA1110-5EF32-0AM0 without rewiring?

No. The 3VA1110 series is a physically smaller frame with different mounting dimensions and bus-bar spacing. The 3VA2010-6HN36-0DL0 is a larger 100 A frame; it will not fit the same cutout or bus connection without panel rework.

What compliance documentation does this brand provide for 3VA2010-6HN36-0DL0 (RoHS, REACH, UL, IEC)?

Siemens provides CE marking, UL/CSA listing, and RoHS/REACH declarations for the SENTRON 3VA series. Specific documentation can be obtained from the manufacturer or through your sourcing channel.

MPN