Specifications

3VA2010-6HN36-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20106HN360AA0
3VA2010-6HN36-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-6HN36-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-6HN36-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6HN36-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-6HN36-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6HN36-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for high-fault panel builds

Maximum power loss runs 13.5 W — negligible for panel thermal budgeting but worth knowing if you're packing breakers tight in a non-ventilated enclosure.

Shunt trip and temperature profile

The base switch is order code 3VA20106HN360AA0, so any accessory or spare-part lookup should start there. Operating temperature range is -25 °C to 70 °C, and the continuous current rating holds flat at 100 A all the way from 40 °C up to 70 °C — no derating curve to chase in warm cabinets.

The 3VA2010-6HN36-0KA0 measures 105 mm wide by 181 mm tall by 86 mm deep — a standard SENTRON 3VA frame size that drops into existing panel layouts without re-drilling gland plates. Three-pole configuration covers three-phase line feeds; the width matches the typical 105 mm pitch for busbar connection.

Frequently asked questions

Where can I buy 3VA2010-6HN36-0KA0 and get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the breaking capacity of this MCCB at 240 V and 415 V?

Breaking capacity is 242 kA at 240 V AC and 187 kA at 415 V AC — high enough for most transformer-secondary and large-busway fault-current scenarios.

Does this breaker have a shunt trip?

Yes, it is fitted with a shunt trip (STL) release for remote tripping via a control voltage.