Siemens 3VA2010-6HN42-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6HN42-0AF0 Circuit Breaker, 100A, 85kA @ 415

MPN3VA2010-6HN42-0AF0

Siemens 3VA2 IEC frame 100 circuit breaker, breaking capacity class H, Icu=85kA @ 415V, 4-pole, ETU350 LSI trip unit, In=100A, overload Ir=40A...100A, short-circuit Isd=1.5...10 x Ir, Ii=12 x In, N conductor protection adjustable, with 1 auxiliary switch changeover H and 1 trip alarm switch changeover.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker brings to the panel

The Siemens 3VA2010-6HN42-0AF0 is a 4-pole IEC frame 100 circuit breaker with an ETU350 LSI electronic trip unit. Rated In=100A, it covers overload protection adjustable from 40A to 100A and short-circuit protection from 1.5 to 10 times Ir, with instantaneous pickup fixed at 12 x In. The 85kA breaking capacity at 415V (class H) means it can safely interrupt high fault currents without cascading upstream — a key spec for main or tie breakers in industrial distribution panels where SCCR headroom matters.

What the ETU350 trip unit gives you in the field

The ETU350 is an LSI (Long-time, Short-time, Instantaneous) electronic trip unit. Long-time pickup (Ir) is adjustable from 40A to 100A — that's the continuous current rating you set for the connected load. Short-time pickup (Isd) adjusts from 1.5 to 10 times Ir, with a time delay that allows coordination with downstream breakers. Instantaneous (Ii) is fixed at 12 x In, covering bolted faults. Neutral conductor protection is adjustable: OFF, 50%, or 100% of phase current. That's useful on 4-wire systems where you need to protect the neutral against harmonics or unbalanced loads.

Integrated aux and alarm contacts

The breaker ships with one auxiliary switch (changeover H) and one trip alarm switch (changeover). That means you get a status contact for remote indication of the breaker position (open/closed) and a separate contact that signals when the breaker has tripped on a fault. No need to order add-on blocks for basic remote monitoring — it's already on the van.

Panel integration notes

Mounts on a standard DIN rail or can be panel-mounted via the frame's integral lugs. The 4-pole footprint takes up four module widths on the rail. Terminal capacity accepts cable sizes typical for 100A circuits — plan for lug or busbar connections per the manufacturer's torque specs. The nut keeper kit (included) helps retain the terminal screws during wiring, which saves time on the panel assembly line.

Frequently asked questions

Where can I buy 3VA2010-6HN42-0AF0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ to get a firm price and lead time.

What is the breaking capacity of 3VA2010-6HN42-0AF0?

The breaker has an Icu of 85kA at 415V, which is class H breaking capacity. That means it can safely interrupt fault currents up to 85,000 amps at 415V AC — suitable for high-fault-capacity industrial mains or sub-distribution panels.

What does the ETU350 LSI trip unit protect against?

The ETU350 provides LSI protection: Long-time (overload, Ir adjustable 40-100A), Short-time (short-circuit with time delay, Isd adjustable 1.5-10 x Ir), and Instantaneous (bolted fault, Ii fixed at 12 x In). It also includes adjustable neutral protection (OFF, 50%, 100% of phase current).

MPN
3VA2010-6HN42-0AF0