Skip to main content
Siemens 3VA2010-6HN46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6HN46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 242

MPN3VA2010-6HN46-0AA0
Active

Siemens SENTRON 3VA2010-6HN46-0AA0, molded case circuit breaker, 4-pole, 100 A rated continuous current, 242 kA breaking capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-6HN46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2010-6HN46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-6HN46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-6HN46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-6HN46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2010-6HN46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-6HN46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens 3VA2010-6HN46-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. Rated 100 A continuous current with four poles, it handles fault interruption up to 242 kA at 240 V — that rating means it clears high-energy faults on the line side without upstream damage, a key spec for panel SCCR coordination. The ETU350 overcurrent release provides electronic trip adjustment, giving selectivity flexibility downstream.

Breaking capacity across voltages — what it means for your system

Breaking capacity drops with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The 690 V figure is the limiting case — if your installation runs at that voltage, verify the available fault current stays under 3 kA, or step up to a higher-rated frame. The 100 A rating holds flat across ambient temperatures from 40 °C to 70 °C (–), so no derating needed in a warm enclosure.

Physical fit and panel integration

Dimensions are 86 mm deep, 140 mm wide, 181 mm high. Four-pole MCCB of this width typically occupies a standard MCCB slot in a distribution panel; the 140 mm width matches the common footprint for a 4-pole 100 A frame. Front IP40 protection means it is splash-safe from the front but not sealed — keep it inside the enclosure, not in a washdown zone.

Frequently asked questions

What is the breaking capacity of 3VA2010-6HN46-0AA0 at 240 V?

242 kA at 240 V. At 415 V and 440 V it is 187 kA; at 500 V it is 121 kA; at 690 V it drops to 3 kA.

How do I get pricing and availability for 3VA2010-6HN46-0AA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

MPN
3VA2010-6HN46-0AA0