Siemens 3VA2010-6JP32-0AA0 SENTRON MCCB, 100 A, 3-pole, ETU5

MPN3VA2010-6JP32-0AA0
Active

Siemens SENTRON 3VA molded case circuit breaker, order code 3VA2010-6JP32-0AA0, 100 A, 3-pole, ETU550 electronic trip unit, 242 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6JP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2010-6JP32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-6JP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2010-6JP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6JP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-6JP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6JP32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2010-6JP32-0AA0 is a SENTRON 3VA molded case circuit breaker (MCCB) in the line-protection version, rated for a permanent current of 100 A across the full ambient range of -25 °C to 70 °C. Breaking capacity is the headline: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The ETU550 electronic trip unit allows adjustable N-conductor protection (OFF or 20 % to 160 % of the rated current), and the unit includes a communication function for integration into a plant-wide power monitoring system.

The 3VA2010-6JP32-0AA0 is a fixed-pattern MCCB designed for panel mounting. The ETU550 release provides adjustable long-time, short-time, instantaneous, and ground-fault protection curves — set these per the coordination study before commissioning. The communication function (likely PROFIBUS or PROFINET via a communication module) enables remote trip indication and current metering. No trip indicator is fitted on this variant, so fault diagnostics rely on the communication interface or a separate status contact.

Frequently asked questions

What trip unit does 3VA2010-6JP32-0AA0 use?

The ETU550 electronic trip unit, which provides adjustable long-time, short-time, instantaneous, and ground-fault protection, plus adjustable N-conductor protection from OFF to 20 % to 160 % of the rated current.

Does 3VA2010-6JP32-0AA0 have a communication function?

Yes, this variant includes a communication function, enabling remote monitoring and integration into a power management system via a compatible communication module.

MPN
3VA2010-6JP32-0AA0