Skip to main content
Siemens 3VA2010-6JP46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6JP46-0AA0 SENTRON MCCB, 100 A, 4-Pole, ETU5

MPN3VA2010-6JP46-0AA0
Active

Siemens SENTRON 3VA2010-6JP46-0AA0, molded case circuit breaker, 4-pole, 100 A, ETU550 electronic trip unit, 242 kA breaking capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6JP46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2010-6JP46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-6JP46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-6JP46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6JP46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-6JP46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6JP46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The ETU550 electronic trip unit gives adjustable long-time, short-time, instantaneous, and ground-fault protection curves. That means selectivity tuning downstream of a transformer or upstream of a motor control center is possible without swapping the breaker — you dial in the curve to match the load. Communication function is built in, so the breaker reports status and trip events to a BMS or PLC over the fieldbus without an add-on module.

The 140 mm width for a 4-pole frame is standard for this class.

Frequently asked questions

What trip unit does this breaker use?

It uses the ETU550 electronic trip unit, which provides adjustable long-time, short-time, instantaneous, and ground-fault protection curves. Communication function is built in.

MPN
3VA2010-6JP46-0AA0