Skip to main content
Siemens 3VA2010-6KP46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6KP46-0AA0 SENTRON MCCB, 100 A, 4-Pole, ETU8

MPN3VA2010-6KP46-0AA0
Active

Siemens SENTRON 3VA2010-6KP46-0AA0, molded case circuit breaker, 4-pole, 100 A, ETU850 electronic trip unit, breaking capacity 242 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6KP46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2010-6KP46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-6KP46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-6KP46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6KP46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-6KP46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6KP46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The interrupting ratings tell you where this breaker can be installed without cascading upstream. At 240 V it clears 242 kA — that's utility-grade fault current, typical for a main or large feeder in a 240 V distribution board. At 415 V and 440 V it still holds 187 kA, and at 500 V it manages 121 kA. The drop to 3 kA at 690 V means it is not a 690 V main breaker — at that voltage it protects a downstream branch with limited fault current.

Frequently asked questions

Where can I buy 3VA2010-6KP46-0AA0 and get a price?

We source this MCCB to order against an RFQ. Submit a request for quote through our site; availability and current pricing are confirmed at quote time.

What are the key ratings of 3VA2010-6KP46-0AA0?

Rated continuous current is 100 A with no derating from 40 °C to 70 °C. Breaking capacity reaches 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 3 kA at 690 V. It is a 4-pole MCCB with an ETU850 electronic trip unit and communication capability.

MPN
3VA2010-6KP46-0AA0