Skip to main content
Siemens 3VA2010-8KP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-8KP32-0AA0 MCCB, 100 A, 150 kA @ 415 V

MPN3VA2010-8KP32-0AA0
Active

Siemens SENTRON 3VA2 series, Molded Case Circuit Breaker (MCCB), 3-pole, IEC frame 100, breaking capacity class L, Icu=150kA @ 415 V, line protection, ETU850 LSI trip unit, In=100 A, adjustable Ir=40 A…100 A, Isd=0.6…10x In, Ii=1.5…12x In.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-8KP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2010-8KP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.7.7 W
3VA2010-8KP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-8KP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-8KP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-8KP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-8KP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2010-8KP32-0AA0 is a SENTRON molded case circuit breaker from the IEC frame 100 family, rated for line protection with a breaking capacity class L — Icu of 150 kA at 415 V.

The breaker measures 105 mm wide, 181 mm high, and 86 mm deep.

Power loss and environment

Storage temperature range is -40 °C to 80 °C; operating range is -25 °C to 70 °C. Insulation voltage rated at 800 V.

Frequently asked questions

What is the breaking capacity of 3VA2010-8KP32-0AA0 at 415 V?

The ultimate breaking capacity Icu at 415 V is 330 kA.

MPN
3VA2010-8KP32-0AA0