Siemens 3VA2010-8KP36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2010-8KP36-0AA0 MCCB, 100 A, 3-Pole, 440

MPN3VA2010-8KP36-0AA0
Active

Siemens SENTRON 3VA series, Molded case circuit breaker, 3VA2010-8KP36-0AA0, 3-pole, 100 A rated, ETU850 electronic trip unit, 440 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-8KP36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2010-8KP36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.7.7 W
3VA2010-8KP36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2010-8KP36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-8KP36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-8KP36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-8KP36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-8KP36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to the top of the enclosure's thermal curve. The breaking capacity hits 440 kA at 240 V and still holds 330 kA at 415 V or 440 V, which puts it squarely in high-fault-duty main or feeder positions.

At 690 V the breaker still interrupts 52.5 kA, which covers most 690 V industrial bus applications. For selective coordination studies, the ETU850 provides the adjustable I²t and short-time delay settings needed to cascade with downstream Sentron 3VA or 3VL breakers. The IP40 front protection is typical for panel-mount — no special gasketing needed for dry indoor switchgear.

Dimensions are 105 mm wide × 181 mm tall × 86 mm deep — standard 3-pole MCCB footprint for the 3VA platform. No undervoltage release or voltage trip module fitted from factory, but the optional motor drive extension is listed as available. The breaker ships without a ground-fault monitoring module, so if you need GF protection, that's an add-on accessory. Communication function is onboard, so it can talk to a PLC or BMS directly via the 3VA communication module interface.

Frequently asked questions

What is the breaking capacity of 3VA2010-8KP36-0AA0 at different voltages?

Breaking capacity is 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V.

What trip unit does this MCCB use?

It uses the ETU850 electronic trip unit, which provides adjustable overload and short-circuit protection curves with communication capability.

Where can I buy 3VA2010-8KP36-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2010-8KP36-0AA0