Skip to main content
Siemens 3VA2025-5HN36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2025-5HN36-0AA0 SENTRON MCCB, 25 A, 3-Pole, ETU35

MPN3VA2025-5HN36-0AA0
Active

Siemens SENTRON 3VA2025-5HN36-0AA0, molded case circuit breaker, 3-pole, 25 A continuous rating, ETU350 electronic trip unit, 187 kA at 240 V, 121 kA at 415/440 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2025-5HN36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2025-5HN36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.84 W
3VA2025-5HN36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2025-5HN36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2025-5HN36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2025-5HN36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2025-5HN36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2025-5HN36-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection — no ground-fault monitoring, no undervoltage release, no communication module, just a straight 3-pole thermal-magnetic (electronic trip ETU350) breaker carrying 25 A continuous at 40-70 °C without derating. Breaking capacity is the headline here: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, dropping to 75.6 kA at 500 V and 3 kA at 690 V. The 3 kA at 690 V is the ceiling; if your system runs 690 V line-to-line, verify the prospective fault current stays under that. Rated insulation voltage is 800 V, operating voltage 690 V AC — so the breaker is electrically rated for 690 V line work, but the interrupting capability at that voltage is limited.

Panel fit and physical integration

Dimensions: 105 mm wide, 181 mm tall, 86 mm deep. Three-pole footprint matches standard MCCB spacing; no special bus adapter needed for most SENTRON distribution blocks. Power loss is 0.84 W max — negligible for thermal budgeting inside a sealed enclosure, but if you're packing multiple breakers in a small cabinet, sum the losses and check the temperature rise against the 70 °C operating max.

Frequently asked questions

Will 3VA2025-5HN36-0AA0 drop into a panel designed for 5SQ2370-2YA05?

Not directly — the 5SQ2370 series is a different frame and trip architecture. The 3VA2025 uses an ETU350 electronic trip unit and has different mounting and bus-bar spacing. Rewiring and a new mounting adapter are needed.

MPN