Skip to main content
Siemens 3VA2025-5JP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2025-5JP32-0AA0 SENTRON MCCB, 25 A, 3-Pole, ETU55

MPN3VA2025-5JP32-0AA0
Active

Siemens SENTRON 3VA2025-5JP32-0AA0, molded case circuit breaker, 25 A rated continuous, 3-pole, ETU550 electronic trip unit, line protection design, 187 kA SCCR at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2025-5JP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2025-5JP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.84 W
3VA2025-5JP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2025-5JP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2025-5JP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2025-5JP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2025-5JP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for 25 A feeder protection with ETU550 smarts

The Siemens SENTRON 3VA2025-5JP32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 25 A continuous current, built around the ETU550 electronic trip unit. The 187 kA interrupting rating at 240 V and 121 kA at 415 V mean this breaker can sit at the main or a high-fault subfeed without worrying about series rating gaps. Rated insulation voltage is 800 V, so it handles 480Y/277 V and 600 V delta systems comfortably.

The interrupting ratings span the voltage range a panel builder actually sees: 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. For a 25 A feeder on a 480 V system, the 121 kA at 440 V is the closest published point — that's well above typical available fault current in most commercial and light industrial panels. If your transformer is oversized or you're sitting close to a 2 MVA unit, the 75.6 kA at 500 V still covers the worst case. No need for a current-limiting fuse ahead of this breaker unless the available fault exceeds those numbers.

Panel fit — 86 mm depth, 105 mm wide

The breaker body measures 86 mm deep, 105 mm wide, and 181 mm tall. That 105 mm width is standard for a 3-pole MCCB in this class — it occupies three 35 mm DIN spaces if mounted on a DIN rail, or bolts directly to a mounting plate. Power loss is just 0.84 W, so no special ventilation is needed in a standard enclosure.

Communication function onboard

This variant includes a communication function, which means it can integrate with a BMS or PLC for remote monitoring and trip-event logging. The ETU550 trip unit supports the communication interface — no separate module required for basic data. If you need remote open/close control, verify the specific communication protocol (PROFIBUS, PROFINET, Modbus) against your system; the order code suffix determines which protocol is fitted.

Frequently asked questions

What is the interrupting rating of 3VA2025-5JP32-0AA0 at 240 V?

187 kA at 240 V. At 415 V and 440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it is 3 kA.

What trip unit does the 3VA2025-5JP32-0AA0 use?

It uses the ETU550 electronic trip unit, which provides adjustable overload and short-circuit protection curves.

Does this breaker have communication capability?

Yes, it includes a communication function for remote monitoring and trip-event logging via the ETU550 trip unit.

How do I get pricing and availability for 3VA2025-5JP32-0AA0?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and confirmed availability at quote time.

MPN
3VA2025-5JP32-0AA0