Skip to main content
Siemens 3VA2025-6HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2025-6HN32-0AA0 SENTRON MCCB, 25 A, 3-Pole, 242 k

MPN3VA2025-6HN32-0AA0
Active

Siemens SENTRON 3VA2025-6HN32-0AA0, molded case circuit breaker, 3-pole, 25 A rated continuous, 242 kA interrupting at 240 V, ETU350 electronic trip unit, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2025-6HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2025-6HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.84 W

Protection & Trip Unit

3VA2025-6HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2025-6HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2025-6HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2025-6HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2025-6HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2025-6HN32-0AA0 is a 3-pole molded case circuit breaker rated for 25 A continuous current across the full ambient range of 40 °C to 70 °C — no derating needed up to that ceiling. Its interrupting capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V — figures that cover most low-voltage fault scenarios in industrial distribution. The ETU350 electronic trip unit provides adjustable overload and short-circuit protection, making this a line-protection breaker suited for feeder circuits in panelboards and switchgear.

Mounting and integration

The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard SENTRON 3VA footprint that fits existing DIN-rail or screw-mount panel layouts without rework. Front face carries IP40 protection, sufficient for enclosed panel environments; no additional sealing required for typical industrial control cabinets. Rated insulation voltage of 800 V aligns with 690 V system applications, and the 300 A maximum/minimum frame rating indicates this is a 300 A frame size, not a 25 A frame — meaning the physical footprint is the same as higher-current siblings in the same frame.

Frequently asked questions

What is the closest functional second-source for 3VA2025-6HN32-0AA0?

The peer MPNs 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 are listed as similar, but they belong to a different Siemens series (5SQ2). Verify footprint and trip-unit compatibility before substituting — the 3VA uses an ETU350 electronic trip, while the 5SQ2 series may use a different release design.

MPN
3VA2025-6HN32-0AA0