Skip to main content
Siemens 3VA2025-6JQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2025-6JQ32-0AA0 MCCB, 25 A, 3-pole, 242 k

MPN3VA2025-6JQ32-0AA0
Active

Siemens SENTRON 3VA series, Molded case circuit breaker, 3VA2025-6JQ32-0AA0, 25 A, 3-pole, ETU560 electronic trip unit, 242 kA at 240 V, 187 kA at 415 V, IP40 front, communication-capable.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2025-6JQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2025-6JQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.84 W
3VA2025-6JQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
3VA2025-6JQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2025-6JQ32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2025-6JQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2025-6JQ32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2025-6JQ32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 25 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to 70 °C, which simplifies panel layout in warm enclosures. The ETU560 electronic trip unit gives adjustable N-conductor protection (OFF, 40 % to 160 %) and supports communication functions for integration into a monitored distribution system. Breaking capacity is the headline: 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The 690 V rating at 3 kA is lower but still covers most 690 V motor circuits in European-style installations. Dimensions are 181 mm high, 105 mm wide, 86 mm deep — standard SENTRON 3VA footprint for a 3-pole frame, so it drops into existing panel cutouts and busbar systems without surprises.

Integration and compliance notes

Spring-cage or screw terminals accept copper conductors sized for 25 A — typical for feeder or branch protection in a 400 V distribution board. Compliance documentation: as a current-production Siemens SENTRON MCCB, it ships with CE marking, UL/CSA recognition per the 3VA series listing, and RoHS/REACH declarations. The ETU560 electronic trip unit is field-configurable for N-conductor protection settings, which is useful for 3-phase 4-wire systems where neutral protection must be coordinated.

Frequently asked questions

Where can I buy 3VA2025-6JQ32-0AA0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time figure is published here, but the part is actively manufactured.

What is the breaking capacity of 3VA2025-6JQ32-0AA0 at different voltages?

242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V AC.

What trip unit does this MCCB use?

It uses the ETU560 electronic trip unit with adjustable N-conductor protection (OFF, 40 % to 160 %) and communication function capability.

MPN
3VA2025-6JQ32-0AA0