Skip to main content
Siemens 3VA2025-7HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2025-7HL32-0AA0 SENTRON MCCB, 25 A, 3-Pole, ETU32

MPN3VA2025-7HL32-0AA0
Active

Siemens SENTRON 3VA2025-7HL32-0AA0, molded case circuit breaker, 3-pole, 25 A rated, ETU320 electronic trip unit, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2025-7HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2025-7HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.5 W
3VA2025-7HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2025-7HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2025-7HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2025-7HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2025-7HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The 86 mm depth, 105 mm width, and 181 mm height fit standard SENTRON 3VA panel cutouts. The 0.5 W maximum power loss is negligible for thermal budgeting inside a crowded enclosure.

Trip unit and thermal performance

The ETU320 is an electronic overcurrent release with adjustable pickup and time-delay curves. Minimum adjustable trip is 38 A, maximum is 300 A, which covers a wide motor or feeder range within the 25 A frame's thermal limits. Insulation voltage rated at 800 V gives headroom for 690 V systems, though the breaking capacity at 690 V drops to 3 kA — that's the limit of the arc chamber in this frame size.

Panel fit and interchange check

Mounts in the standard SENTRON 3VA panel footprint — same 105 mm width and 86 mm depth as the 3VA2116 frame. If a panel was cut for a 3VA2116-5HL32-0AK0, this 3VA2025 drops into the same DIN-rail or screw-mount pattern without rewiring.

MPN