Skip to main content
Siemens 3VA2025-7JQ46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2025-7JQ46-0AA0 SENTRON MCCB, 25 A, 4-Pole, 330 k

MPN3VA2025-7JQ46-0AA0
Active

Siemens SENTRON 3VA2025-7JQ46-0AA0, molded case circuit breaker, 4-pole, 25 A continuous rating, adjustable thermal overload 38-300 A, 330 kA interrupting at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2025-7JQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2025-7JQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.5 W
3VA2025-7JQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2025-7JQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2025-7JQ46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2025-7JQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2025-7JQ46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Its adjustable thermal overload range spans 38 A minimum to 300 A maximum, meaning you set the actual trip point anywhere within that window to match the downstream load — useful when the same breaker frame covers multiple feeder sizes across a facility. Interrupting capacity is specified per voltage: 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3 kA at 690 V. For a 25 A frame, these numbers give generous headroom for selectivity coordination downstream. The unit includes onboard communication capability for integration into a monitoring or control network, and its ground-fault monitoring uses summation current formation on the L + N conductor, so it detects leakage without a separate GFCI module.

Thermal performance across ambient temperature

Storage extremes span -40 °C to 80 °C. Maximum power loss is 0.5 W, negligible for panel thermal budgeting.

As a SENTRON-series MCCB, the 3VA2025-7JQ46-0AA0 carries the standard Siemens compliance documentation package: RoHS and REACH declarations, plus the relevant IEC/UL certifications typical for this product class. Specific cert numbers are available with the full datasheet on request.

Frequently asked questions

What are the key ratings for this MCCB?

Continuous current is 25 A with an adjustable thermal overload range of 38 A to 300 A. Interrupting capacity reaches 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3 kA at 690 V. It is a 4-pole unit with onboard communication and ground-fault summation monitoring.

Where can I buy the 3VA2025-7JQ46-0AA0 and get current pricing?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment.

Will the 3VA2025-7JQ46-0AA0 drop into a panel specified for the 3VA2125-8KQ42-0AA0?

Both are 4-pole SENTRON MCCBs in the same frame family, so the physical footprint and mounting pattern are identical. The deciding factor is the rating: the 3VA2025-7JQ46-0AA0 is a 25 A unit with adjustable thermal range 38-300 A, while the 3VA2125-8KQ42-0AA0 carries different ratings. Verify the required continuous current and interrupting capacity against your coordination study before swapping.

What compliance documentation does Siemens provide for this MCCB?

Standard documentation includes RoHS and REACH declarations plus IEC/UL certifications typical for the SENTRON series. The insulation voltage is rated 800 V. Full cert copies and the datasheet are available on request with an RFQ.

MPN
3VA2025-7JQ46-0AA0