Skip to main content
Siemens 3VA2040-4JQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-4JQ42-0AA0 SENTRON MCCB, 40A 4P ETU560, 121k

MPN3VA2040-4JQ42-0AA0

Siemens SENTRON 3VA2040-4JQ42-0AA0, molded case circuit breaker, 4-pole, 40 A, ETU560 electronic trip unit, line protection, 121 kA at 240 V, 76 kA at 415 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2040-4JQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2040-4JQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V76 kA
Breaking capacity at 440 V76 kA
Breaking capacity at 500 V53 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W
3VA2040-4JQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
3VA2040-4JQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-4JQ42-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2040-4JQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-4JQ42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

SENTRON 3VA2040-4JQ42-0AA0 — 40 A 4-pole MCCB with ETU560 electronic trip unit

The Siemens SENTRON 3VA2040-4JQ42-0AA0 is a 4-pole molded case circuit breaker rated for 40 A continuous current across the full operating temperature range from -40 °C to 70 °C, with no derating needed at elevated panel temperatures. It carries the ETU560 electronic trip unit, which supports adjustable long-time pickup and delay settings (tr from 0.5 s to 25 s), plus configurable N-conductor protection (OFF, 40 %, or 160 % of phase rating) — making it suited for line-feeder duty where coordination with downstream breakers matters. The interrupting ratings are 121 kA at 240 V, 76 kA at 415 V and 440 V, 53 kA at 500 V, and 3 kA at 690 V — the 415 V figure covers the common 400 V class panel bus, giving solid SCCR headroom for transformer-fed distribution. Communication function is onboard (the ETU560 supports the SENTRON communication-capable platform), and ground fault monitoring uses summation current sensing on L+N conductors.

Sourcing and lifecycle — active, with a direct peer for panel swaps

The 3VA2040-4JQ42-0AA0 shares the same 4-pole SENTRON 3VA frame dimensions (86 mm deep, 140 mm wide, 181 mm high) and ETU560 trip platform as the 3VA2140-8JQ42-0AA0.

The envelope is 86 mm deep by 140 mm wide by 181 mm high (3.4 in × 5.5 in × 7.1 in), fitting standard SENTRON 3VA panel cutouts for 4-pole frames. Maximum power loss is 2.2 W, so internal panel heating from this breaker is negligible even in dense layouts.

Frequently asked questions

What compliance documentation does Siemens provide for this MCCB?

As a SENTRON 3VA series breaker, it carries the expected IEC/UL certifications for the class. Specific RoHS, REACH, and UL documentation is available from Siemens directly or through the distributor upon RFQ.

MPN
3VA2040-4JQ42-0AA0