Skip to main content
Siemens 3VA2040-5HL32-0BE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-5HL32-0BE0 SENTRON MCCB, 40 A, 3-Pole, ETU32

MPN3VA2040-5HL32-0BE0

Siemens SENTRON 3VA2040-5HL32-0BE0 molded case circuit breaker, 3-pole, 40 A, ETU320 electronic trip unit, with undervoltage release, 187 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2040-5HL32-0BE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20405HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2040-5HL32-0BE0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.4.7 W
3VA2040-5HL32-0BE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2040-5HL32-0BE0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-5HL32-0BE0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2040-5HL32-0BE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-5HL32-0BE0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2040-5HL32-0BE0 — 40 A SENTRON MCCB with ETU320 and Undervoltage Release

The Siemens 3VA2040-5HL32-0BE0 is a SENTRON molded case circuit breaker (MCCB) rated for 40 A continuous at 40 °C through 70 °C — the current rating holds flat across the entire operating temperature range, so no derating curve to track for standard panel ambient conditions. It carries an ETU320 electronic trip unit with an adjustable current range from 60 A minimum to 480 A maximum, though the breaker frame itself is rated for 40 A continuous; the trip unit settings govern the overload and short-circuit protection thresholds within that frame rating. Breaking capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — the 187 kA figure at 240 V is the highest interrupting rating on this unit, suitable for high-fault utility or transformer-fed downstream panels where available fault current exceeds 100 kA.

The 40 A continuous rating at 40–70 °C means this breaker can be installed in a warm enclosure — say, a panel near a motor drive or transformer — without needing to step up to a 50 A frame to compensate for ambient temperature. The ETU320 electronic trip unit provides adjustable long-time, short-time, and instantaneous protection, plus ground-fault alarm or trip if configured; the minimum setting of 60 A on the trip unit is above the 40 A frame rating, so the trip unit is set for a higher current than the breaker's continuous rating — this is typical for MCCBs where the frame rating is the thermal limit and the trip unit is set to protect downstream conductors. The 187 kA interrupting rating at 240 V is the key number for high-fault installations — if the available fault current at the panel is, say, 150 kA, this breaker clears it without needing a current-limiting fuse upstream. At 480 V or 600 V class systems, the 121 kA at 415/440 V and 75.6 kA at 500 V still cover most industrial service-entrance and distribution panel scenarios. The 3 kA at 690 V is a low figure — this breaker is not intended for 690 V high-fault applications; use a higher-voltage-rated MCCB for that.

The 3-pole design with 105 mm width fits standard 3-pole MCCB spacing in a distribution panel. The undervoltage release (UVR) is factory-integrated — no field-assembly of the release mechanism required. The ETU320 trip unit is the electronic version with a rotary dial for adjustment; it does not include a communication function or voltage trigger, so remote trip indication is via the auxiliary contacts only.

Frequently asked questions

How do I get current pricing and availability for 3VA2040-5HL32-0BE0?

We source the 3VA2040-5HL32-0BE0 to order against an RFQ. Submit a request for quote and we will confirm current pricing and availability at that time.

What is the breaking capacity of 3VA2040-5HL32-0BE0 at different voltages?

The breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. The 187 kA at 240 V is the highest rating, suitable for high-fault utility feeds.

Does 3VA2040-5HL32-0BE0 include an undervoltage release?

Yes, this variant includes a factory-installed undervoltage release (UVR) that trips the breaker when control voltage drops below threshold. It also has 4 auxiliary switches HQ for status feedback.

MPN
3VA2040-5HL32-0BE0