Siemens 3VA2040-5KP42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-5KP42-0AA0 SENTRON MCCB, 4P 40A ETU850, 187k

MPN3VA2040-5KP42-0AA0
Active

Siemens SENTRON 3VA2040-5KP42-0AA0, 4-pole molded case circuit breaker, 40 A continuous, ETU850 electronic trip unit, 187 kA breaking capacity at 240 VAC, IP40 front protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2040-5KP42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2040-5KP42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W
3VA2040-5KP42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2040-5KP42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-5KP42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2040-5KP42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-5KP42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Integrator's spec recap — 3VA2040-5KP42-0AA0

Its interrupting capacity hits 187 kA at 240 VAC and 121 kA at 415/440 VAC — numbers that govern the available fault current the installation can handle without upstream coordination issues. The breaker includes a communication function (likely for remote monitoring or trip indication via the ETU850's optional modules), though no specific protocol is listed in the base spec. Front IP40 protection suits panel-mount applications; no IP rating on the sides means the enclosure must keep dust and moisture out.

Breaking capacity by voltage — selectivity headroom

The 3VA2040-5KP42-0AA0 delivers 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V. That steep drop above 500 V is typical for an MCCB with a 40 A frame — the arc extinction limits at higher line-to-line voltages. For a 480 V wye system (277 V line-to-neutral), the 187 kA rating at 240 V is not directly applicable; the 75.6 kA at 500 V is the relevant figure. Coordination studies should use the 500 V column for 480 V panels.

Mounting and integration — panel fit

The ETU850 trip unit is field-adjustable for long-time, short-time, instantaneous, and ground-fault pickup. The communication function occupies the accessory slot on the front.

MPN