Skip to main content
Siemens 3VA2040-5KQ46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-5KQ46-0AA0 SENTRON MCCB, 40 A, 4-Pole, 187 k

MPN3VA2040-5KQ46-0AA0
Active

Siemens SENTRON 3VA2040-5KQ46-0AA0, molded case circuit breaker, 4-pole, 40 A rated continuous current, line protection design, adjustable thermal-magnetic trip 60-480 A, breaking capacity 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2040-5KQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2040-5KQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W

Protection & Trip Unit

3VA2040-5KQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes

Construction & Connection

3VA2040-5KQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2040-5KQ46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2040-5KQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2040-5KQ46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2040-5KQ46-0AA0 is a 4-pole molded case circuit breaker rated for 40 A continuous current, designed for line protection in distribution panels. Its adjustable thermal-magnetic trip unit covers a 60 A to 480 A range, letting you dial in the overload and short-circuit settings to match the downstream load without swapping the breaker body. Breaking capacity is the headline here: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. That 187 kA at 240 V means it can safely interrupt a fault current of that magnitude — critical for high-fault installations like large transformer secondaries or industrial service entrances where available fault current is high. Rated current holds flat at 40 A from 40 °C all the way to 70 °C ambient — no derating needed in a warm enclosure, which simplifies panel thermal calculations. The breaker includes a communication function and ground-fault monitoring via summation current formation on L+N conductors.

Panel integration

Dimensions are 86 mm deep, 140 mm wide, 181 mm tall — fits standard 4-pole MCCB panel cutouts. The 140 mm width is the same footprint as other SENTRON 3VA2 frame breakers, so a panel laid out for a 3VA2063-8JQ42-0AA0 accepts this one without re-drilling the mounting plate or re-routing bus bars.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

187 kA at 240 V, which covers high-fault installations like large transformer secondaries or industrial service entrances.

Where can I buy 3VA2040-5KQ46-0AA0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does this breaker require derating in high ambient temperatures?

No derating needed — the 40 A rating holds flat from 40 °C to 70 °C ambient. That simplifies panel thermal calculations in warm enclosures.

MPN
3VA2040-5KQ46-0AA0