Skip to main content
Siemens 3VA2040-6HN46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-6HN46-0AA0 SENTRON MCCB, 40 A, 480 V, 242 kA

MPN3VA2040-6HN46-0AA0
Active

Siemens SENTRON 3VA2040-6HN46-0AA0, molded case circuit breaker, 4-pole, 40 A, line protection, ETU350 trip unit, 242 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2040-6HN46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2040-6HN46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W
3VA2040-6HN46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2040-6HN46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-6HN46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2040-6HN46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-6HN46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens 3VA2040-6HN46-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 40 A continuous current with a maximum breaking capacity of 242 kA at 240 V.

This MCCB's interrupting rating drops with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The 3 kA at 690 V is the weak point — verify the available fault current at that voltage before specifying for 690 V applications.

Rated current and thermal performance

Continuous current rating holds at 40 A across the full operating temperature range from -25 °C to 70 °C, with no derating needed.

Dimensions: 181 mm high, 140 mm wide, 86 mm deep. The 4-pole width of 140 mm is standard for SENTRON 3VA2 frames — verify the existing panel cutout and DIN rail alignment if replacing a different brand or older series. No undervoltage release or communication module fitted on this variant.

Frequently asked questions

What is the breaking capacity of 3VA2040-6HN46-0AA0 at 240 V?

242 kA at 240 V, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V.

Where can I buy 3VA2040-6HN46-0AA0 and how is it quoted?

Sourced to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock or lead-time figures published here.

Does 3VA2040-6HN46-0AA0 require derating at elevated temperatures?

No — the 40 A rating holds across the full operating range from -25 °C to 70 °C with no derating.

MPN
3VA2040-6HN46-0AA0