3VA2040-6JP36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2040-6JP36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W
3VA2040-6JP36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
3VA2040-6JP36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-6JP36-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2040-6JP36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-6JP36-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

The ETU550 electronic trip unit gives you adjustable time-current curves — tr min 0.5 s, tr max 25 s, tsd max 0.5 s — so you can dial in selectivity with downstream breakers without swapping hardware.

Breaking capacity and voltage class

The interrupting ratings tell you where this MCCB fits in the fault-current hierarchy: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. At 690 V the capacity drops sharply — that 3 kA figure means it is not a primary choice for 690 V distribution unless the available fault current is known to be low.

Thermal performance across temperature

Maximum power loss is 2.2 W, which is negligible for panel heat budgeting.

Frequently asked questions

Where can I buy 3VA2040-6JP36-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2040-6JP36-0AA0 at 415 V?

187 kA at 415 V.

What trip unit does 3VA2040-6JP36-0AA0 use?

It uses the ETU550 electronic trip unit with adjustable time-current settings: tr min 0.5 s, tr max 25 s, tsd max 0.5 s.