Skip to main content
Siemens 3VA2040-6KP36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-6KP36-0AA0 SENTRON MCCB, 40 A, 242 kA at 240

MPN3VA2040-6KP36-0AA0
Active

Siemens SENTRON 3VA2040-6KP36-0AA0, molded case circuit breaker, 3-pole, 40 A rated continuous current, 242 kA interrupting at 240 V, ETU850 electronic release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2040-6KP36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2040-6KP36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W

Protection & Trip Unit

3VA2040-6KP36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850

Construction & Connection

3VA2040-6KP36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2040-6KP36-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2040-6KP36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2040-6KP36-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

The Siemens 3VA2040-6KP36-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, 3-pole, with a rated continuous current Iu of 40 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its interrupting capacity reaches 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V — figures that place it in the high-fault-current class for industrial distribution panels where upstream transformer capacity or fault current is substantial. The ETU850 electronic overcurrent release provides adjustable time-current curves: tr from 0.5 s to 25 s, tsd up to 0.5 s, giving the commissioning engineer room to coordinate with downstream breakers without nuisance tripping.

Integration and mounting

Dimensions: 105 mm wide, 181 mm high, 86 mm deep — fits standard panel-mount cutouts for a 3-pole MCCB in this frame size. Front face protection is IP40, suitable for enclosed panel installation where no washdown or dust ingress is expected. Rated insulation voltage Ui of 800 V; operating temperature range from -40 °C to 70 °C, storage from -40 °C to 80 °C.

Key ratings and what they mean

The 40 A rating holds flat across the ambient range — no thermal derating curve to calculate, which simplifies panel design for high-ambient environments like motor control centers. The 242 kA interrupting capacity at 240 V means this breaker can safely clear a fault at that current level without rupturing — essential for installations close to large transformers or with high available fault current. Mechanical endurance of 20 000 cycles and a maximum power loss of 2.2 W per pole indicate a design suited for frequent switching applications where heat dissipation in the enclosure matters. Communication function and other measurement function are present on this variant, allowing integration with energy management systems via the SENTRON communication platform.

MPN
3VA2040-6KP36-0AA0