Siemens 3VA2040-7JP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-7JP32-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU55

MPN3VA2040-7JP32-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2040-7JP32-0AA0, 40 A continuous, 3-pole, ETU550 electronic trip unit, line protection design, with communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2040-7JP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2040-7JP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3 kA
Power loss, max.1.2 W
3VA2040-7JP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2040-7JP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-7JP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2040-7JP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-7JP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2040-7JP32-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 40 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its 3-pole construction and ETU550 electronic trip unit make it a line-protection breaker with communication capability, suited for main or feeder duty in distribution panels where you need adjustable protection curves and remote monitoring.

This MCCB delivers 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3 kA at 690 V. For 400 V-class panels (the common industrial distribution voltage), the 242 kA interrupting rating covers virtually any utility transformer size you'll encounter.

The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep — a 3-pole MCCB footprint that fits standard Siemens 3VA switchboard and panelboard mounting.

Trip unit and communication

The communication function enables integration with energy management systems or PLCs via the 3VA communication modules, allowing remote trip indication, current metering, and parameter adjustment. No undervoltage release, voltage trigger, or trip indicator is fitted from the factory; those are field-addable accessories if your application requires them.

MPN
3VA2040-7JP32-0AA0