Skip to main content
Siemens 3VA2040-8JP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-8JP32-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU55

MPN3VA2040-8JP32-0AA0
Active

Siemens SENTRON 3VA2040-8JP32-0AA0, molded case circuit breaker, 3-pole, 40 A continuous, ETU550 electronic trip unit, adjustable 60–480 A, breaking capacity 440 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2040-8JP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2040-8JP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.1.2 W

Protection & Trip Unit

3VA2040-8JP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2040-8JP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2040-8JP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2040-8JP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2040-8JP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB with flat thermal derating and wide trip range

The Siemens 3VA2040-8JP32-0AA0 is a SENTRON molded case circuit breaker sized for 40 A continuous current across the full ambient range — it holds 40 A from 40 °C all the way up to 70 °C, so no derating curve to chase in a warm panel. The ETU550 electronic trip unit lets you set the overload threshold anywhere from 60 A to 480 A, which means one SKU covers multiple load sizes on the BOM. Breaking capacity runs 440 kA at 240 V, 330 kA at 415/440 V, 220 kA at 500 V, and 52.5 kA at 690 V — high enough for most distribution and motor branch circuits without an upstream current-limiting fuse.

Panel fit and integration

Three-pole footprint: 105 mm wide, 181 mm tall, 86 mm deep. Mounts on a DIN rail or direct-panel with the standard SENTRON lug kit. IP40 on the front — fine for enclosed distribution boards; not rated for washdown. The ETU550 supports communication functions, so you can pull trip events and load data into a BMS or PLC without adding a separate meter.

Lifecycle and sourcing

Current-production part — no end-of-life notice on this order code. Sourced to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Frequently asked questions

What is the breaking capacity of 3VA2040-8JP32-0AA0 at 415 V?

330 kA at 415 V, and the same 330 kA at 440 V. At 240 V it is 440 kA, at 500 V it is 220 kA, and at 690 V it is 52.5 kA.

Does 3VA2040-8JP32-0AA0 have communication capability?

Yes, the ETU550 trip unit supports communication functions for remote monitoring of trip events and load data.

Where can I buy 3VA2040-8JP32-0AA0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2040-8JP32-0AA0