Skip to main content
Siemens 3VA2040-8KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2040-8KQ42-0AA0 SENTRON MCCB, 40 A, 4-Pole, 440 k

MPN3VA2040-8KQ42-0AA0
Active

Siemens SENTRON molded case circuit breaker, 3VA2040-8KQ42-0AA0, 40 A, 4-pole, line protection design, 440 kA interrupting at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2040-8KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2040-8KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.1.2 W

Protection & Trip Unit

3VA2040-8KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes

Construction & Connection

3VA2040-8KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2040-8KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2040-8KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2040-8KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

40 A, 4-pole SENTRON MCCB — line protection with communication

The Siemens SENTRON 3VA2040-8KQ42-0AA0 is a 4-pole molded case circuit breaker rated for 40 A continuous current, designed specifically for line protection in distribution panels. It carries a 440 kA interrupting capacity at 240 V, stepping down to 330 kA at 415/440 V and 220 kA at 500 V, with 52.5 kA at 690 V — giving you selectivity headroom across common low-voltage distribution voltages. The breaker includes an onboard communication function and summation ground-fault monitoring (L+N conductor), so it fits into monitored distribution schemes without an external module.

SCCR and thermal performance across the panel temperature band

Rated continuous current holds flat at 40 A from 40 °C through 70 °C ambient — no derating needed within that window, which simplifies panel thermal budgeting. The 4-pole footprint measures 140 mm wide by 181 mm tall by 86 mm deep, fitting standard Siemens SENTRON mounting patterns. Insulation voltage is rated 800 V, so the breaker is comfortable in 480/277 V and 600 V nominal systems with margin.

Frequently asked questions

What is the interrupting capacity of 3VA2040-8KQ42-0AA0 at 240 V?

440 kA at 240 V, stepping to 330 kA at 415/440 V, 220 kA at 500 V, and 52.5 kA at 690 V.

Where can I buy 3VA2040-8KQ42-0AA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Does 3VA2040-8KQ42-0AA0 include ground-fault monitoring?

Yes, it has summation current ground-fault monitoring on the L+N conductor.

MPN
3VA2040-8KQ42-0AA0