Skip to main content
Siemens 3VA2063-5HL32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HL32-0CH0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5HL32-0CH0

Siemens SENTRON 3VA2063-5HL32-0CH0, molded case circuit breaker, 3-pole, 63 A rated current, line protection, 187 kA breaking capacity at 240 V, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5HL32-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2063-5HL32-0CH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.7.9 W
3VA2063-5HL32-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2063-5HL32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5HL32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2063-5HL32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5HL32-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Line Protection MCCB with Undervoltage Release

The Siemens SENTRON 3VA2063-5HL32-0CH0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. The interrupting ratings are substantial: 187 kA at 240 V AC, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

Built-In Undervoltage Protection and Auxiliary Switching

The trip indicator is present, so a visual flag confirms the breaker opened on a fault versus being manually switched off. No communication function or ground-fault monitoring is included on this order code — it is a pure line-protection device with undervoltage release.

The 86 mm depth means it clears most shallow enclosures, but verify the door clearance for the rotary handle if used in a dead-front switchboard. Power loss is rated at 7.9 W maximum, which is modest for a 63 A frame; thermal management inside a sealed panel is straightforward.

Frequently asked questions

Where can I buy 3VA2063-5HL32-0CH0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ with your quantity and target delivery — availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2063-5HL32-0CH0 at different voltages?

The interrupting ratings are 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

Does 3VA2063-5HL32-0CH0 include an undervoltage release?

Yes, it ships with an integrated undervoltage release (UVR) as the auxiliary release type.

MPN
3VA2063-5HL32-0CH0