Skip to main content
Siemens 3VA2063-5HL32-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HL32-0HA0 Circuit Breaker, 63A, 55kA

MPN3VA2063-5HL32-0HA0

Siemens 3VA2 IEC frame 100, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU320 LI, In=63A, overload Ir=25A...63A, short-circuit Ii=1.5...12 x In, with nut keeper kit and shunt trip (STL) 12-30V DC, 24V AC 50/60Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What's in the box

The Siemens 3VA2063-5HL32-0HA0 is a current-production IEC molded-case circuit breaker on the 3VA2 platform, frame 100, with a 55 kA interrupting capacity at 415 V — that's the M breaking capacity class, meaning it handles moderate fault levels typical of industrial distribution panels without cascading upstream. Three poles, line protection via the ETU320 electronic trip unit with LI (long-time and instantaneous) curves. Rated continuous current In = 63 A, with overload protection adjustable Ir from 25 A to 63 A, and short-circuit pickup Ii adjustable 1.5 to 12 times In. Ships with the nut keeper kit and a shunt trip (STL) coil rated 12–30 V DC or 24 V AC 50/60 Hz.

The ETU320 is an electronic trip unit, so it holds its calibration over temperature better than a thermal-magnetic; the LI curve gives you adjustable long-time pickup (Ir) for cable protection and adjustable instantaneous (Ii) for motor-start inrush or selective coordination. The shunt trip (STL) on 12–30 V DC or 24 V AC lets you remote-trip from an E-stop or PLC output without a separate interposing relay. Mounts in a standard IEC panel on a DIN rail or direct-screw pattern — verify the frame-100 footprint against your existing bus bars.

Frequently asked questions

Where can I buy 3VA2063-5HL32-0HA0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery window.

What is the interrupting rating of this breaker?

The 3VA2063-5HL32-0HA0 has an Icu of 55 kA at 415 V AC, which places it in breaking capacity class M on the 3VA2 frame.

What trip unit and adjustments does this breaker have?

It uses an ETU320 electronic trip unit with LI (long-time and instantaneous) protection. Overload Ir is adjustable from 25 A to 63 A, and short-circuit pickup Ii is adjustable from 1.5 to 12 times In.

Does this breaker include a shunt trip?

Yes, it includes a shunt trip (STL) coil rated for 12–30 V DC or 24 V AC 50/60 Hz, plus a nut keeper kit.

MPN
3VA2063-5HL32-0HA0