Skip to main content
Siemens 3VA2063-5HL32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HL32-0JH0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2063-5HL32-0JH0

Siemens SENTRON 3VA2063-5HL32-0JH0, 3-pole molded case circuit breaker, 63 A rated continuous current Iu, ETU320 electronic trip unit, 187 kA breaking capacity at 240 V AC, with integrated shunt trip (STL) and HQ auxiliary switch package.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5HL32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2063-5HL32-0JH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.5.4 W
3VA2063-5HL32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2063-5HL32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5HL32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2063-5HL32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5HL32-0JH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2063-5HL32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 63 A at 40 °C and holding that rating up to 50 °C before derating starts. Breaking capacity hits 187 kA at 240 V, 121 kA at 415/440 V, 79 kA at 500 V, and 3.4 kA at 690 V — numbers that tell you this breaker was designed for high-fault industrial distribution, not light commercial panels.

The 63 A continuous rating with no derating through 50 °C means you can load this breaker to full nameplate in a warm enclosure without bumping up a frame size. At 55 °C it's 60.6 A, at 70 °C it's 53.6 A — so the thermal curve is gradual, not a cliff. The 187 kA interrupting rating at 240 V is the headline number, but for most 400 V-class industrial plants the relevant figure is 121 kA at 415 V — that's the SCCR you coordinate against downstream feeder breakers. Rated insulation voltage Ui of 800 V tells you the internal clearances and creepage are designed for 690 V systems, which matches the 3.4 kA breaking capacity at that voltage — it's not a 690 V workhorse, but it will clear a fault on a 690 V line.

Trip unit and auxiliary configuration

The ETU320 is the base electronic trip in the 3VA range — no communication, no ground-fault monitoring, no phase-failure detection. It's a straightforward adjustable electronic release for line protection. The shunt trip is the supplied basic switch 3VA2063-5HL32-0AA0, and the auxiliary trip module is 3VA9688-0BL32 — both factory-integrated, so no field assembly required.

Frequently asked questions

What is the 3VA2063-5HL32-0JH0's depth?

86 mm — measure your enclosure depth against that figure, accounting for busbar and wiring clearance behind the breaker.

MPN
3VA2063-5HL32-0JH0