Siemens 3VA2063-5HL36-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HL36-0AD0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5HL36-0AD0

Siemens SENTRON 3VA2063-5HL36-0AD0, molded case circuit breaker, 3-pole, 63 A continuous rating, line protection design, interrupting capacity 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5HL36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2063-5HL36-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-5HL36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5HL36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5HL36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2063-5HL36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5HL36-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens 3VA2063-5HL36-0AD0 is a SENTRON molded case circuit breaker (MCCB) sized for line protection in distribution panels. It carries a continuous rated current of 63 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel sizing in warm enclosures. Three poles handle three-phase circuits. The interrupting capacity is what decides where this breaker lands in a selective coordination study: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. That 187 kA figure at 240 V is high — it sits this breaker upstream of most downstream devices without needing a current-limiting fuse ahead of it. Rated insulation voltage is 800 V. The basic switch supplied is order code 3VA20635HL360AA0, with three auxiliary switches (HQ). No undervoltage release, no ground-fault monitoring, no communication function.

Panel fit and footprint

Dimensions are 181 mm high, 105 mm wide, 86 mm deep. The 105 mm width is the standard 3-pole MCCB footprint for this SENTRON frame size.

Frequently asked questions

Does this breaker include an undervoltage release or ground-fault monitoring?

No. This variant has no undervoltage release and no ground-fault monitoring. It is a straight line-protection breaker with three auxiliary switches (HQ type).

MPN
3VA2063-5HL36-0AD0