Skip to main content
Siemens 3VA2063-5HL36-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HL36-0AH0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5HL36-0AH0

Siemens SENTRON 3VA2 series, molded case circuit breaker, order code 3VA2063-5HL36-0AH0, 63 A continuous, 3-pole, line protection, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5HL36-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2063-5HL36-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W
3VA2063-5HL36-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2063-5HL36-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5HL36-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2063-5HL36-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5HL36-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2063-5HL36-0AH0 is a SENTRON 3VA2 molded case circuit breaker rated for 63 A continuous current across the full ambient range from -25 °C to 70 °C — no derating needed up to that ceiling.

Interrupting capacity by voltage level

This MCCB delivers 187 kA interrupting capacity at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. At 690 V it still clears, but only for low-fault installations.

Auxiliary switching and trip indication

The trip indicator gives a local mechanical flag — no separate voltage trigger or undervoltage release is included, so if you need remote shunt trip or UVR, that has to be added externally. No communication function onboard; this is a standalone breaker, not a metering or power-monitoring device.

No special cutout required beyond the standard 3VA2 footprint. The 5.4 W maximum power loss is modest; ventilation around the breaker is still advisable if it's grouped with other high-current devices in a sealed enclosure.

Frequently asked questions

What is the interrupting capacity of 3VA2063-5HL36-0AH0 at 415 V?

121 kA at 415 V AC. The same rating applies at 440 V.

Does this breaker include undervoltage release or shunt trip?

No. The 3VA2063-5HL36-0AH0 ships without undervoltage release and without a voltage trigger. Those are external accessories.

What auxiliary switches come fitted on this MCCB?

Two auxiliary switches plus one trip alarm switch (HQ type) are factory-installed.

Where can I buy 3VA2063-5HL36-0AH0 and how is it quoted?

Sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3VA2063-5HL36-0AH0