Skip to main content
Siemens 3VA2063-5HL36-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HL36-0BC0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5HL36-0BC0

Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3VA2063-5HL36-0BC0, 63 A rated continuous current, 3-pole, line protection, with undervoltage release and 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5HL36-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2063-5HL36-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.7.9 W

Protection & Trip Unit

3VA2063-5HL36-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5HL36-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5HL36-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2063-5HL36-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5HL36-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

63 A SENTRON MCCB — line protection with undervoltage release

The Siemens 3VA2063-5HL36-0BC0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to the 70 °C operating maximum. That makes it a drop-in for panels where ambient heat buildup is a concern; the breaker holds its full 63 A rating even in a warm cabinet. Three-pole construction with a line-protection design means it's configured for feeder or branch-circuit duty, not motor protection. The interrupting ratings are substantial: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. At 240 V, that 187 kA covers high-fault scenarios near the transformer secondary without cascading upstream. It ships with an integrated undervoltage release (UVR) and two auxiliary switches in HQ configuration. The UVR trips the breaker when control voltage drops below a set threshold — useful for safety circuits or coordinated shutdown sequences. The auxiliary switches provide status feedback (open/closed) to a PLC or indication lamp.

Frequently asked questions

What does the 'HL36' in the order code signify?

The order code suffix encodes the release type, auxiliary switch configuration, and accessories. Specifically, this variant includes an undervoltage release (UVR) and two auxiliary switches in HQ configuration. The basic switch itself is order code 3VA20635HL360AA0.

MPN
3VA2063-5HL36-0BC0