Siemens 3VA2063-5HN32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HN32-0BH0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5HN32-0BH0

Siemens SENTRON 3VA2063-5HN32-0BH0 molded case circuit breaker, 3-pole, 63 A continuous, 187 kA interrupting at 240 V, line protection design with undervoltage release and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5HN32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2063-5HN32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.7.9 W

Protection & Trip Unit

3VA2063-5HN32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5HN32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5HN32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2063-5HN32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5HN32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens SENTRON 3VA2063-5HN32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across an ambient temperature range from -25 °C to 70 °C — no derating needed up to the full 70 °C, which simplifies panel design in warm enclosures. Its interrupting capacity is 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V. That 187 kA at 240 V is the headline number — it tells you this breaker handles high-fault scenarios at low voltage without needing a current-limiting fuse upstream. At 415 V the 121 kA still covers most industrial distribution panels. This variant is designed for line protection (cable/feeder protection), not motor protection — so it's the right choice for a main or distribution breaker in a panel feeding downstream branch circuits. It includes an undervoltage release (UVR) that trips the breaker when supply voltage drops below a set threshold, which is useful for safety circuits or preventing automatic restart after a power loss.

Auxiliary switching and trip indication

The breaker ships with 2 auxiliary switches plus 1 trip alarm switch (HQ type), giving you remote status feedback for open/closed and tripped conditions. The trip indicator is mechanical — visible on the front of the breaker even without power. No communication function is built in; this is a conventional thermal-magnetic or electronic-trip MCCB, not a smart breaker with Modbus or PROFINET.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep. That 105 mm width is standard for a 3-pole SENTRON 3VA2 frame — it mounts on a DIN rail or can be screw-mounted to a backplate. The 86 mm depth means it fits in shallow enclosures where a deeper MCCB would hit the door or gland plate. Power loss is rated at 7.9 W maximum — low enough that you don't need forced ventilation in most panels, but worth checking if you're packing multiple breakers in a small enclosure at elevated ambient.

Lifecycle and sourcing reality

The base switch variant is 3VA20635HN320AA0 — the -0BH0 suffix adds the specific auxiliary switch and undervoltage release configuration. Mounting footprint and bus-bar spacing are consistent across the 3VA2 series.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, it comes with an undervoltage release (UVR) that trips the breaker when supply voltage drops below the release threshold.

MPN