Skip to main content
Siemens 3VA2063-5HN36-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2063-5HN36-0AG0 Molded Case Circuit Break

MPN3VA2063-5HN36-0AG0

Siemens SENTRON 3VA2063-5HN36-0AG0, molded case circuit breaker, 3-pole, 63 A continuous, 187 kA interrupting at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5HN36-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2063-5HN36-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-5HN36-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5HN36-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5HN36-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2063-5HN36-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5HN36-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

63 A MCCB with flat thermal derating and high fault-current capacity

The Siemens SENTRON 3VA2063-5HN36-0AG0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel thermal calculations in tight enclosures. Its interrupting capacity hits 187 kA at 240 V, dropping to 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V — the 240 V figure covers most North American 120/208 V and 277/480 V panelboard applications with ample headroom for high-fault locations like utility interfaces or large motor control centers. Rated insulation voltage is 800 V, so it's suited for 480/277 V and 600 V systems with margin; the line-protection design (not motor or feeder) means the trip curve is optimized for cable and busbar protection rather than motor inrush.

Footprint and auxiliary switch configuration

The breaker measures 105 mm wide by 181 mm tall by 86 mm deep — a 3-pole footprint that fits standard SENTRON panel cutouts and busbar arrangements. Depth of 86 mm (3.39 in) is shallow enough for most distribution boards without requiring deep enclosures. It ships with one auxiliary switch and one trip alarm switch (HP type) factory-installed, providing status feedback for PLC or building management inputs without additional wiring labor. No undervoltage release, no ground-fault monitoring, and no communication module on this variant — it's a straight line-protection breaker with basic signaling. Maximum power loss is 5.4 W, which keeps heat dissipation low enough for dense panel layouts without forced ventilation in most installations.

Lifecycle and sourcing

The base switch assembly carries order code 3VA20635HN360AA0; the -0AG0 suffix denotes the specific auxiliary switch and trip alarm configuration. For BOM matching, verify the auxiliary contact arrangement matches your existing panel wiring — the HP-type switch has a defined contact sequence that differs from standard auxiliary-only variants.

Environmental and compliance

Operating temperature range is -25 °C to 70 °C, with storage from -40 °C to 80 °C — suitable for unconditioned electrical rooms and outdoor enclosures in most climates. The 70 °C operating ceiling matches the flat derating curve, so no current reduction is needed even at the top of the range. As a Siemens SENTRON product, compliance documentation covers IEC/EN 60947-2, UL 489, CSA C22.2 No. 5, and CE marking. RoHS and REACH declarations are available from Siemens documentation portals.

Frequently asked questions

What are the key ratings for this breaker?

63 A continuous current (no derating from 40 °C to 70 °C), 3-pole, 187 kA interrupting at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, 3 kA at 690 V. Rated insulation voltage is 800 V.

What is the depth of this breaker?

86 mm (3.39 in). Shallow enough for standard distribution boards without deep enclosures.

What auxiliary switches come with this breaker?

One auxiliary switch and one trip alarm switch, both HP type, factory-installed. No undervoltage release or ground-fault monitoring on this variant.

Where can I buy 3VA2063-5HN36-0AG0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
3VA2063-5HN36-0AG0