Siemens 3VA2063-5HN36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HN36-0HC0 SENTRON MCCB, 63 A, 3-pole, ETU35

MPN3VA2063-5HN36-0HC0

Siemens SENTRON 3VA2063-5HN36-0HC0, molded case circuit breaker (MCCB), 3-pole, 63 A, ETU350 electronic trip unit, line protection, 187 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5HN36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-5HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2063-5HN36-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.5.4 W
3VA2063-5HN36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2063-5HN36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5HN36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2063-5HN36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5HN36-0HC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Breaking capacity across voltages

At 415 V and 440 V the breaker holds 121 kA, dropping to 79 kA at 500 V, and 3.4 kA at 690 V.

Thermal derating and ambient tolerance

Rated full 63 A from 40 °C through 50 °C, then derates linearly: 60.6 A at 55 °C, 58.3 A at 60 °C, 55.9 A at 65 °C, and 53.6 A at 70 °C. That 70 °C ceiling means it takes the radiant heat near a furnace or drive cabinet without forced cooling — a real advantage on a hot-strip mill floor where ambient near the rolls melts ordinary gear.

Trip unit and auxiliary configuration

The integrated auxiliary trip is order code 3VA9688-0BL30. No undervoltage release or voltage trigger is present; the voltage trigger option is listed as yes, meaning it can accept a shunt trip coil for remote tripping.

Mounts on DIN rail or direct panel mount. Latching endurance is rated at 20,000 operations. Max power loss is 5.4 W.

Current production — no obsolescence notice. For volume or BOM-freeze inquiries, submit an RFQ.

Frequently asked questions

Will 3VA2063-5HN36-0HC0 drop into a panel specified around 3VA2163-5HL32-0JB0?

Not without checking the frame size and mounting. The 3VA2063 is a different frame than the 3VA2163 series; verify the physical footprint and bus-bar spacing before substitution.

MPN