Skip to main content
Siemens 3VA2063-5HN36-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HN36-0HL0 SENTRON MCCB, 63 A, 3-pole, ETU35

MPN3VA2063-5HN36-0HL0

Siemens SENTRON 3VA2063-5HN36-0HL0, molded case circuit breaker, 3-pole, 63 A, ETU350 electronic trip unit, line protection, 187 kA at 240 V, 121 kA at 415 V, shunt trip (STL), 2 aux + 1 trip alarm + 1 electrical alarm HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5HN36-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-5HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2063-5HN36-0HL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.5.4 W
3VA2063-5HN36-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2063-5HN36-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5HN36-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2063-5HN36-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5HN36-0HL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

SENTRON 3VA2063-5HN36-0HL0 — 63 A MCCB with ETU350, 3-pole, line protection

The Siemens 3VA2063-5HN36-0HL0 is a 3-pole molded case circuit breaker from the SENTRON 3VA2 series, rated for a continuous current Iu of 63 A and fitted with an ETU350 electronic trip unit. The ETU350 provides adjustable long-time, short-time, and instantaneous protection curves, plus a built-in voltage trigger for shunt-trip coordination.

Deployment and integration

The shunt trip (STL) integrated release allows remote tripping from an emergency-stop circuit or a PLC digital output — no separate undervoltage release is fitted, so the breaker will not drop out on a control-voltage dip unless the shunt is intentionally energized. The ETU350 is self-powered from the line current; no external control power is needed for the trip unit to operate.

Thermal derating and endurance

Above 50 °C the current must be derated: 60.6375 A at 55 °C, 58.275 A at 60 °C, 55.9125 A at 65 °C, and 53.55 A at 70 °C.

Frequently asked questions

How do I get current pricing and availability for 3VA2063-5HN36-0HL0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 3VA2063-5HN36-0HL0's listed depth (86 mm) on this component line?

The depth is 86 mm, measured from the mounting surface to the front of the breaker body (excluding handle projection).

What is 3VA2063-5HN36-0HL0's listed width (105 mm) on this component line?

The width is 105 mm, which is the standard 3-pole MCCB footprint for this frame size.

Will 3VA2063-5HN36-0HL0 drop into a panel that was specified around 3VA2163-5HL32-0JB0 without rewiring?

No. Both breakers share the same 3-pole frame and 105 mm width, but the auxiliary contact wiring differs. The 3VA2063-5HN36-0HL0 has two auxiliary switches plus a trip alarm and an electrical alarm (HQ), while the 3VA2163-5HL32-0JB0 has a different auxiliary contact arrangement. The terminal assignments for the alarm contacts will not match, so rewiring of the control circuit is required.

What compliance documentation does this brand provide for 3VA2063-5HN36-0HL0 (RoHS, REACH, UL, IEC)?

Siemens SENTRON 3VA2 series breakers are designed to meet IEC 60947-2 and UL 489 standards. RoHS and REACH declarations are available from Siemens on request. The interrupting ratings listed (187 kA at 240 V, 121 kA at 415 V) are based on IEC testing; UL/CSA interrupting ratings may differ and should be verified from the specific UL file.

MPN