Skip to main content
Siemens 3VA2063-5HN36-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5HN36-0KL0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5HN36-0KL0

Siemens SENTRON 3VA2063-5HN36-0KL0, molded case circuit breaker, 3-pole, 63 A, 187 kA at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5HN36-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2063-5HN36-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-5HN36-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5HN36-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5HN36-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2063-5HN36-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5HN36-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries and where it fits

The Siemens 3VA2063-5HN36-0KL0 is a 3-pole SENTRON molded case circuit breaker rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V, so it handles high-fault service-entrance or distribution positions where SCCR headroom matters. The line-protection design means it's tuned for cable and busbar protection, not motor overload curves. Max power loss is 5.4 W, which keeps heat out of a crowded enclosure.

Panel fit and integration

Footprint is 181 mm high by 105 mm wide by 86 mm deep. It's a standard MCCB form factor for DIN-rail or panel-mount backplate layouts. The auxiliary switch block ships as 2 auxiliary switches plus 1 trip alarm and 1 electrical alarm switch (HQ configuration), and a shunt trip (STL) release is built in for remote tripping. No undervoltage release on this variant. Operating range is -25 °C to 70 °C; storage from -40 °C to 80 °C.

Frequently asked questions

What is the interrupting capacity of 3VA2063-5HN36-0KL0 at 240 V?

187 kA at 240 V, which drops to 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

Where can I buy 3VA2063-5HN36-0KL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What auxiliary switches does 3VA2063-5HN36-0KL0 include?

It ships with 2 auxiliary switches plus 1 trip alarm switch and 1 electrical alarm switch (HQ configuration), plus a shunt trip (STL) release.

MPN
3VA2063-5HN36-0KL0