SENTRON 3VA2063-5JQ32-0CH0 MCCB, 63 A, 3P, 187 kA at 240 V

MPN3VA2063-5JQ32-0CH0

SENTRON 3VA2063-5JQ32-0CH0, 3-pole molded case circuit breaker, 63 A rated, interrupting 187 kA at 240 V, with undervoltage release and communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5JQ32-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2063-5JQ32-0CH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.7.9 W
3VA2063-5JQ32-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2063-5JQ32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5JQ32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2063-5JQ32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5JQ32-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The SENTRON 3VA2063-5JQ32-0CH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a full-scale current of 63 A across the entire ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Interrupting capacity hits 187 kA at 240 V, drops to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and still holds 3 kA at 690 V.

Built-in extras that save panel space

That means you don't need to carve out extra DIN rail for add-on modules — the UVR handles safety-related dropouts, and the auxiliary contacts feed status back to the PLC or annunciator without a separate interposing relay. Communication function is onboard, so it can talk to a higher-level system for metering or remote trip indication.

Depth of 86 mm keeps the back-of-panel clearance manageable, even with wiring gutters.

Frequently asked questions

How do I get current pricing and availability for 3VA2063-5JQ32-0CH0?

Submit an RFQ through the storefront; the part is sourced and quoted to order, with availability and current pricing confirmed at quote time.

What is 3VA2063-5JQ32-0CH0's interrupting capacity at 240 V?

187 kA at 240 V, dropping to 121 kA at 415 V / 440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

What is the closest functional second-source for 3VA2063-5JQ32-0CH0?

The 3VA2063-8JQ32-0AA0 is a close peer — same frame, same 63 A rating, same 3-pole configuration. The main difference is the auxiliary switch configuration and the absence of the undervoltage release on the -8AA0 variant. It will drop into the same panel footprint without rewiring.

MPN