Siemens 3VA2063-5JQ32-0DA0 — Molded Case Circuit Breakers (MCCB)

3VA2063-5JQ32-0DA0 SENTRON MCCB, 63 A, 187 kA at 240 V

MPN3VA2063-5JQ32-0DA0

Siemens SENTRON 3VA2063-5JQ32-0DA0, molded case circuit breaker, 3-pole, 63 A, 187 kA at 240 V, ETU560 electronic trip unit, line protection version, undervoltage release, communication capable.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5JQ32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-5JQ32-0AA0
3VA2063-5JQ32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.7.9 W
3VA2063-5JQ32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
3VA2063-5JQ32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5JQ32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-5JQ32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5JQ32-0DA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this 3VA2063-5JQ32-0DA0 is

It's the line protection version — meaning it's set up for feeder or main breaker duty, not motor circuit protection.

63 A continuous at 40 °C is the baseline — but this breaker doesn't derate much until above 55 °C, where it steps down to 60.6 A at 55 °C and 53.6 A at 70 °C. That thermal stability matters in a sealed enclosure or a panel near a heat source.

That's a standard MCCB footprint — it'll drop into most 3VA-series panel cutouts or DIN-rail mounting adapters. The 105 mm width means it takes up three pole spaces in a typical distribution panel. The undervoltage release (UVR) is built in, so no separate add-on module to wire. Communication function is on board — check the ETU560 manual for the protocol (likely PROFIBUS or PROFINET via a communication module).

Frequently asked questions

What trip unit does 3VA2063-5JQ32-0DA0 use?

ETU560 electronic trip unit. It provides adjustable overload (Ir), short-time (Isd), and instantaneous (Ii) protection settings, plus ground-fault detection via summation current formation on the L-conductor.

MPN