Skip to main content
Siemens 3VA2063-5KP32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2063-5KP32-0AJ0 MCCB, 63 A, 187 kA

MPN3VA2063-5KP32-0AJ0

Siemens SENTRON molded case circuit breaker, 3VA2063-5KP32-0AJ0, 3-pole, 63 A, ETU850 electronic trip unit, 187 kA at 240 V, 86 x 105 x 181 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-5KP32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-5KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2063-5KP32-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.5.4 W
3VA2063-5KP32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
3VA2063-5KP32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-5KP32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2063-5KP32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-5KP32-0AJ0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Breaking capacity hits 187 kA at 240 V, 121 kA at 415/440 V, 79 kA at 500 V, and 3.4 kA at 690 V — enough for high-fault utility feeds or transformer secondaries without cascading upstream. This is a line-protection version (not motor-protection), so it's sized for feeder or main breaker duty in distribution panels. The ETU850 provides communication and other measurement functions, plus a 2-auxiliary + 1-trip-alarm contact block built in.

Front IP40 protection — suitable for dead-front switchboard mounting, not for washdown environments. Ambient operating range -25 °C to 70 °C; current derating starts at 55 °C (60.6 A) down to 53.55 A at 70 °C. Mechanical endurance 20,000 operations.

The base switch is 3VA2063-5KP32-0AA0.

Frequently asked questions

How do I get pricing and availability for 3VA2063-5KP32-0AJ0?

Sourced and quoted to order against an RFQ through independent distribution. Current pricing and stock confirmed at quote time.

MPN
3VA2063-5KP32-0AJ0