Siemens 3VA2063-5KP32-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5KP32-0HL0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2063-5KP32-0HL0

Siemens SENTRON 3VA2063-5KP32-0HL0, molded case circuit breaker, 3-pole, 63 A continuous, 187 kA at 240 V, line protection with communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5KP32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2063-5KP32-0HL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-5KP32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5KP32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5KP32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2063-5KP32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5KP32-0HL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries and where it fits

The Siemens SENTRON 3VA2063-5KP32-0HL0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from 40 °C through 70 °C — no derating needed up to that ceiling. Its interrupting ratings climb to 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V, and 3 kA at 690 V. That 187 kA figure at 240 V tells you this breaker is built for high-fault panels where downstream coordination matters; the 121 kA at 415 V still covers most industrial distribution boards. The 86 mm depth and 105 mm width fit standard MCCB mounting footprints, and the 181 mm height leaves room for gland plates above.

Line protection with a communication backbone

This breaker is designed for line protection — feeder and distribution circuits — and carries a communication function so it can report status and trip events back to a PLC or BMS. That saves a maintenance tech from walking the panel to read a flag. The auxiliary switch configuration includes 2 auxiliary switches plus a trip alarm switch and an electrical alarm switch, giving you four discrete signals for remote indication. A shunt trip release (STL) is built in, letting a safety relay or emergency-stop circuit drop the breaker remotely. There is no undervoltage release, so if your scheme relies on UVR for undervoltage protection, plan for an external relay.

Environmental and storage limits

Storage temperature spans -40 °C to 80 °C, so it can sit in an unheated warehouse or a hot container without damage. Operating ambient is -25 °C to 70 °C, which covers most indoor panel environments. Maximum power loss is 5.4 W — negligible for panel thermal calculations, but worth noting if you pack multiple breakers in a sealed enclosure.

Trip indication and measurement

A trip indicator and voltage trigger are present, so the breaker gives local and remote trip confirmation. The other measurement function suggests the electronic trip unit can log or communicate additional data like current draw or fault magnitude — useful for predictive maintenance or post-event analysis. The basic switch assembly is order code 3VA20635KP320AA0, which is the internal switching mechanism; if you ever need to replace just that subassembly, that's the part number.

MPN
3VA2063-5KP32-0HL0