Skip to main content
Siemens 3VA2063-5KP32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-5KP32-0JA0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA2063-5KP32-0JA0

Siemens SENTRON 3VA2063-5KP32-0JA0, molded case circuit breaker, 63 A, 3-pole, line protection, with shunt trip release and communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-5KP32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20635KP320AA0

Ratings

3VA2063-5KP32-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-5KP32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-5KP32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-5KP32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2063-5KP32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-5KP32-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2063-5KP32-0JA0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Interrupting capacity reaches 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V, giving you headroom for high-fault industrial distribution panels. The built-in shunt trip release (STL) allows remote tripping, and the communication function supports integration into a monitored power system.

Fit and footprint

Dimensions are 86 mm deep, 105 mm wide, and 181 mm high. That width is standard for a 3-pole MCCB in this class — it fits the same DIN-rail or panel-mount cutout as other SENTRON 3VA2 breakers. The 63 A frame keeps the overall size compact for the interrupting ratings it carries.

Frequently asked questions

How do I get current pricing and availability for 3VA2063-5KP32-0JA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is 3VA2063-5KP32-0JA0's listed depth and width?

Depth is 86 mm, width is 105 mm, and height is 181 mm.

What compliance documentation does this brand provide for 3VA2063-5KP32-0JA0?

As a Siemens SENTRON molded case circuit breaker, this part is designed to meet applicable UL, IEC, RoHS, and REACH standards. Specific certificates are available on request.

MPN
3VA2063-5KP32-0JA0