Skip to main content
Siemens 3VA2063-6HL32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-6HL32-0AG0 SENTRON MCCB, 63A, 242kA IC

MPN3VA2063-6HL32-0AG0

Siemens SENTRON 3VA2063-6HL32-0AG0, molded case circuit breaker, 3-pole, 63 A, 242 kA at 240 V, ETU320 electronic trip unit, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-6HL32-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2063-6HL32-0AG0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4 kA
Power loss, max.5.4 W
3VA2063-6HL32-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2063-6HL32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-6HL32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2063-6HL32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-6HL32-0AG0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What sets it apart is the interrupting capacity: 242 kA at 240 V, 187 kA at 415/440 V, and still 121 kA at 500 V. That means it handles high-fault scenarios where a standard MCCB would fail — think transformer secondaries, large-bus feeds, or utility tie points where available fault current exceeds 100 kA.

Current derating — the real-world continuous rating

Full 63 A is available up to 50 °C ambient. Above that the rating tapers: 60.6 A at 55 °C, 58.3 A at 60 °C, 55.9 A at 65 °C, 53.6 A at 70 °C. If your panel runs hot — enclosed switchgear, high-density layouts — the 55 °C row is likely your design point. The 5.4 W maximum power loss is low enough that you don't need forced cooling for this one breaker in a standard enclosure.

Panel fit — dimensions and auxiliaries

That's a standard 3-pole MCCB slot in most SENTRON distribution boards and panelboards.

Frequently asked questions

What trip unit does the 3VA2063-6HL32-0AG0 use?

The ETU320 electronic trip unit, which provides adjustable long-time, short-time, and instantaneous protection. It is line-protection configured (no voltage trigger, no undervoltage release, no ground-fault monitoring).

Will 3VA2063-6HL32-0AG0 drop into a panel specified around 3VA1010-2ED32-0JA0?

No — the 3VA1010-2ED32-0JA0 is a different frame size and rating class. The 3VA2063 is a 63 A, 3-pole MCCB with a 105 mm width; the 3VA1010 is a smaller frame. They are not mechanically interchangeable without re-drilling mounting holes or changing bus connections.

MPN
3VA2063-6HL32-0AG0