Siemens 3VA2063-6HL32-0BA0 SENTRON MCCB, 63 A, 3-pole, ETU32

MPN3VA2063-6HL32-0BA0

Siemens SENTRON 3VA2063-6HL32-0BA0, molded case circuit breaker, 3-pole, 63 A, ETU320 electronic trip unit, 242 kA at 240 V, 187 kA at 415 V, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-6HL32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2063-6HL32-0AA0
3VA2063-6HL32-0BA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4 kA
Power loss, max.7.9 W
3VA2063-6HL32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2063-6HL32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-6HL32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-6HL32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-6HL32-0BA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

MCCB with ETU320 — selectivity and SCCR headroom

At 63 A continuous current it holds full rating from 40 °C up to 50 °C, then derates to 53.55 A at 70 °C — a thermal curve that matters when the breaker sits in a crowded, warm panel. The interrupting capacity tells the real story: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4 kA at 690 V. That 187 kA at 415 V gives substantial SCCR headroom for downstream coordination in high-fault industrial distribution.

The ETU320 release is electronic (not thermal-magnetic), so trip curves are more precise and adjustable, but the breaker draws 7.9 W maximum power loss, which adds to the enclosure heat budget. No auxiliary contacts or shunt trip on this variant; the undervoltage release (UVR) is built in — verify the control voltage matches your coil supply before wiring. Mechanical endurance is 20 000 operations, adequate for a distribution feeder but not for frequent switching duty.

Frequently asked questions

What is the interrupting capacity of 3VA2063-6HL32-0BA0 at 415 V?

187 kA at 415 V, and the same at 440 V. At 240 V it reaches 242 kA; at 500 V it drops to 121 kA, and at 690 V to 4 kA.

Where can I buy 3VA2063-6HL32-0BA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2063-6HL32-0BA0