Skip to main content
Siemens 3VA2063-6HL32-0HC0 — Molded Case Circuit Breakers (MCCB)

3VA2063-6HL32-0HC0 SENTRON MCCB, 63 A, 3-Pole, 242 kA at 240

MPN3VA2063-6HL32-0HC0

Siemens SENTRON 3VA2063-6HL32-0HC0, molded case circuit breaker, 3-pole, 63 A continuous, 242 kA interrupting at 240 V, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-6HL32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20636HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2063-6HL32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-6HL32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-6HL32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-6HL32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2063-6HL32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-6HL32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The 3VA2063-6HL32-0HC0 is a Siemens SENTRON molded case circuit breaker, designed for line protection in industrial power distribution panels. It's rated for 63 A continuous current across the full ambient temperature range from -25 °C to 70 °C — no derating needed up to that ceiling, which is handy when the panel sits near hot machinery. At 240 V it interrupts 242 kA, at 415 V it's still 187 kA, so it handles serious fault currents without upstream coordination headaches.

Key ratings and what they mean for fit

The 63 A frame is the same across the 3VA2 family, but the interrupting capacity here — 242 kA at 240 V — is the high-end option. That's enough for most secondary distribution panels fed from a large transformer or a generator bus. The 3-pole design handles three-phase loads; the shunt trip (STL) and two auxiliary switches (HQ) let you integrate remote tripping and status feedback into a PLC or safety circuit.

Integration notes

Dimensions: 181 mm high, 105 mm wide, 86 mm deep. That's a standard SENTRON 3VA2 footprint — fits existing DIN-rail or panel-mount cutouts for the series. Spring-cage terminals accept 0.2–2.5 mm² solid or ferruled stranded. The shunt trip coil draws its own power; verify polarity and voltage match the control circuit before energizing.

Frequently asked questions

What is 3VA2063-6HL32-0HC0's interrupting capacity at 240 V?

It interrupts 242 kA at 240 V, which is the high-interrupting option in the 3VA2 family.

Will 3VA2063-6HL32-0HC0 drop into a panel that was specified around 3VA2163-5HL32-0JB0 without rewiring?

Mechanically it fits the same 3VA2 frame cutout, but the 3VA2063 has a higher interrupting capacity (242 kA vs the 3VA2163's lower rating). If the panel was designed for a lower fault level, swapping to this breaker requires a coordination review — don't just drop it in without checking the available fault current.

Where can I buy 3VA2063-6HL32-0HC0?

This part is sourced to order against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time.

MPN
3VA2063-6HL32-0HC0