Skip to main content
Siemens 3VA2063-6HL32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-6HL32-0JH0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2063-6HL32-0JH0

Siemens SENTRON 3VA2063-6HL32-0JH0, molded case circuit breaker, 3-pole, 63 A, line protection, breaking capacity 242 kA at 240 V, 187 kA at 415 V, 121 kA at 500 V, 3 kA at 690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-6HL32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20636HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2063-6HL32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-6HL32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2063-6HL32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-6HL32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2063-6HL32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-6HL32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2063-6HL32-0JH0 — 63 A MCCB for Line Protection

The Siemens SENTRON 3VA2063-6HL32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current, designed for line protection in distribution panels. It carries a 242 kA breaking capacity at 240 V AC, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V — so at typical 400 V class supply voltages it handles high fault currents without cascading upstream. The adjustable thermal-magnetic trip covers 95 A minimum to 756 A maximum, giving selectivity flexibility downstream.

What the Ratings Mean for Your Panel

The 63 A continuous rating holds across the full ambient temperature range from -25 °C to 70 °C — no derating curve to chase at elevated panel temperatures. That's unusual for an MCCB this compact; most competitors start derating above 40 °C. The 3-pole construction fits standard 3-phase distribution, and the 86 mm depth (3.39 in) × 105 mm width (4.13 in) × 181 mm height (7.13 in) footprint is sized for DIN-rail or direct-panel mounting in a typical 600 mm wide enclosure. Maximum power loss is 5.4 W per pole — negligible for thermal budgeting in a sealed enclosure, but worth noting if you're packing multiple breakers in a small gland plate area. The breaker includes a trip indicator and voltage trigger for remote status. It ships with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration) and a shunt trip release (STL) for remote tripping. No undervoltage release, no ground-fault monitoring, no communication module — this is a straightforward line-protection device, not a smart breaker.

Frequently asked questions

Where can I buy 3VA2063-6HL32-0JH0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What are the key ratings for 3VA2063-6HL32-0JH0?

63 A continuous, 3-pole, breaking capacity 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, 3 kA at 690 V. Adjustable trip range 95 A to 756 A. Dimensions: 86 mm deep × 105 mm wide × 181 mm tall.

What compliance documentation does Siemens provide for this MCCB?

The SENTRON 3VA series carries RoHS, REACH, UL, and IEC compliance declarations from Siemens. Specific certificates are available through the manufacturer's documentation portal.

MPN
3VA2063-6HL32-0JH0