Skip to main content
Siemens 3VA2063-6HL36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-6HL36-0AA0 SENTRON MCCB, 63 A, 242 kA at 240

MPN3VA2063-6HL36-0AA0
Active

Siemens SENTRON 3VA2063-6HL36-0AA0, molded case circuit breaker, 63 A rated continuous current, 242 kA breaking capacity at 240 V, ETU320 electronic overcurrent release, 3-pole, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-6HL36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2063-6HL36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W
3VA2063-6HL36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2063-6HL36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-6HL36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-6HL36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-6HL36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its ETU320 electronic overcurrent release handles line protection, with a maximum breaking capacity of 242 kA at 240 V and 187 kA at 415 V (–). That SCCR headroom means it can interrupt high-fault currents without cascading upstream, critical for main feeders or high-capacity distribution panels.

The 3VA2063-6HL36-0AA0 measures 105 mm wide, 181 mm tall, and 86 mm deep — a compact 3-pole footprint that fits standard SENTRON mounting bases and panel cutouts (–, –). Front IP40 protection suits enclosed panel installations; no communication module or undervoltage release is fitted, so it's a straightforward line-protection breaker without auxiliary wiring.

Frequently asked questions

Where can I buy 3VA2063-6HL36-0AA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; current pricing and availability are confirmed at that time.

What is 3VA2063-6HL36-0AA0's listed depth (86 mm) on this component line?

The depth is 86 mm. Combined with the 105 mm width and 181 mm height, it fits standard SENTRON panel cutouts.

Will 3VA2063-6HL36-0AA0 drop into a panel that was specified around 3VA2163-8HM32-0AA0 without rewiring?

Both are 3-pole SENTRON MCCBs in the same physical frame size, so the 105 mm width and 181 mm height are identical — no panel rework for the cutout. However, the 3VA2063-6HL36-0AA0 uses an ETU320 release (line protection) while the 3VA2163-8HM32-0AA0 may have a different release or rating; verify the trip curve and continuous current match your coordination study before swapping.

MPN
3VA2063-6HL36-0AA0