Skip to main content
Siemens 3VA2063-6HN32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-6HN32-0JA0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2063-6HN32-0JA0

Siemens SENTRON molded case circuit breaker, 3VA2063-6HN32-0JA0, 63 A rated current, 3-pole, 242 kA breaking capacity at 240 V AC, with shunt trip release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-6HN32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20636HN320AA0
3VA2063-6HN32-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W
3VA2063-6HN32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2063-6HN32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-6HN32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-6HN32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-6HN32-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2063-6HN32-0JA0 — 63 A SENTRON MCCB with Shunt Trip

The Siemens 3VA2063-6HN32-0JA0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient temperature range from 40 °C to 70 °C, meaning no derating is needed in a warm panel — the breaker holds its 63 A rating all the way up to 70 °C ambient. The breaking capacity is 242 kA at 240 V AC, 187 kA at 415/440 V, 121 kA at 500 V, and 3 kA at 690 V — these are the maximum fault currents the breaker can safely interrupt at each voltage level, so selectivity studies and SCCR calculations should use the voltage-specific value, not the highest one.

The 3VA2063-6HN32-0JA0 measures 105 mm wide, 181 mm high, and 86 mm deep — the 105 mm width is the critical dimension for multi-breaker spacing on a DIN rail or mounting plate; verify the gland plate knockout pattern accommodates this footprint before laying out the panel.

Frequently asked questions

Does 3VA2063-6HN32-0JA0 include a shunt trip?

Yes, it is equipped with a shunt trip release (STL) for remote tripping via a control signal.

MPN
3VA2063-6HN32-0JA0