Siemens 3VA2063-6HN42-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-6HN42-0AF0 Circuit Breaker, 63A, 85kA @ 415V

MPN3VA2063-6HN42-0AF0

Siemens 3VA2 IEC frame 100, breaking capacity class H, 4-pole, line protection ETU350 LSI, In=63A, Icu=85kA @ 415V, with auxiliary switch and trip alarm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA2063-6HN42-0AF0 is a current-production IEC molded case circuit breaker from the 3VA2 family, frame size 100, in a 4-pole configuration. It's built for line protection with an ETU350 electronic trip unit offering LSI protection — long-time, short-time, and instantaneous — adjustable over a wide range: overload protection Ir from 25 A to 63 A, short-circuit protection Isd from 1.5 to 10 times Ir, and instantaneous pickup Ii fixed at 12 times In. The 85 kA breaking capacity at 415 V (class H) means it can safely interrupt faults up to that level without cascading upstream — critical for high-fault panels where you need selectivity and don't want a main breaker tripping on a branch fault.

This breaker ships with a nut keeper kit for panel mounting and includes one auxiliary switch (changeover H) and one trip alarm switch (changeover) factory-fitted — saves a panel-builder having to snap in add-on blocks later. The N-conductor protection is adjustable (OFF or 100%), giving flexibility for different system grounding schemes. Mounts in the standard IEC frame-100 footprint, so it swaps into existing 3VA2 panel cutouts without rework.

The ETU350 trip unit is the same platform used across the 3VA2 line, so settings and accessories are consistent if you're mixing frame sizes in the same panel. The 85 kA @ 415 V rating puts this in the high-breaking-capacity tier — suited for industrial mains distribution where fault current is substantial, not just branch protection downstream of a transformer.

Frequently asked questions

Where can I buy 3VA2063-6HN42-0AF0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA2063-6HN42-0AF0?

The rated ultimate breaking capacity Icu is 85 kA at 415 V AC, which is class H for the 3VA2 frame 100 series.

What trip unit and protection functions does this breaker have?

It uses an ETU350 electronic trip unit with LSI protection: long-time (overload) adjustable Ir 25 A to 63 A, short-time Isd adjustable 1.5 to 10 x Ir, and instantaneous Ii fixed at 12 x In. Neutral conductor protection is adjustable OFF or 100%.

Does this breaker come with auxiliary contacts or alarms?

Yes, it includes one auxiliary switch (changeover H) and one trip alarm switch (changeover) factory-installed.

MPN
3VA2063-6HN42-0AF0