Skip to main content
Siemens 3VA2063-7HM32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2063-7HM32-0AA0 MCCB, 63 A, 330 kA at 240

MPN3VA2063-7HM32-0AA0
Active

Siemens SENTRON 3VA2063-7HM32-0AA0, molded case circuit breaker, 3-pole, 63 A, ETU330 electronic trip unit, 330 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2063-7HM32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2063-7HM32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3 kA
Power loss, max.5.4 W

Protection & Trip Unit

3VA2063-7HM32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330

Construction & Connection

3VA2063-7HM32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2063-7HM32-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2063-7HM32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2063-7HM32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

What the ratings mean for your panel

The Siemens SENTRON 3VA2063-7HM32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel layout in warm enclosures or near other heat sources. Its interrupting capacity hits 330 kA at 240 V and 242 kA at 415 V, so it can sit upstream of a high-fault transformer or a large motor bank without needing a current-limiting fuse ahead of it — the breaker itself clears the fault. The ETU330 electronic trip unit gives adjustable long-time pickup and delay (tr min 0.5 s, tr max 17 s), letting you coordinate selectivity with downstream feeders rather than relying on a fixed thermal curve.

Panel fit and dimensions

At 105 mm wide, 181 mm tall, and 86 mm deep (–), the 3VA2063-7HM32-0AA0 fits the standard SENTRON 3VA2 mounting footprint — no special sub-panel or adapter plate needed for a retrofit into an existing 3VA2 cutout. Front-face protection is IP40, adequate for a closed panel; the breaker accepts optional motor-drive extensions for remote tripping or auto-reset schemes.

Frequently asked questions

Will 3VA2063-7HM32-0AA0 drop into a panel specified around 3VA2163-8HM32-0AA0 without rewiring?

Both are SENTRON 3VA2 frame breakers sharing the same mounting footprint and terminal layout, so a direct mechanical swap is possible. However, the 3VA2063-7HM32-0AA0 is a 63 A line-protection version with an ETU330 trip unit, while the 3VA2163-8HM32-0AA0 is a higher-current variant — verify the load-side rating and trip-unit settings before substituting.

MPN
3VA2063-7HM32-0AA0